[DOC] update docu
- HA Modbus interface - exmaple modbus.yaml and template.yaml
This commit is contained in:
+304
@@ -0,0 +1,304 @@
|
||||
- name: pe1_test
|
||||
type: tcp
|
||||
host: xxx.xxx.xxx.xxx
|
||||
port: 502
|
||||
# maybe need 1 second delay after connect for device to get ready
|
||||
#delay: 1
|
||||
sensors:
|
||||
# SYSTEM STATUS
|
||||
- name: Modbus PE1 System Status Enum
|
||||
unique_id: modbus_pe1_system_status_enum
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 4000
|
||||
scan_interval: 30
|
||||
device_class: enum
|
||||
- name: Modbus PE1 Furnace Status Enum
|
||||
unique_id: modbus_pe1_furnace_status_enum
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 4001
|
||||
scan_interval: 30
|
||||
device_class: enum
|
||||
#- name: Modbus PE1 Heating Mode Enum
|
||||
# unique_id: modbus_pe1_heating_mode_enum
|
||||
# slave: 2
|
||||
# input_type: holding
|
||||
# address: 46
|
||||
# count: 18
|
||||
# scan_interval: 30
|
||||
|
||||
# TEMPERATURES
|
||||
- name: Modbus PE1 Hotwater Temperature Top
|
||||
unique_id: modbus_pe1_hotwater_temperature_top
|
||||
slave: 2
|
||||
input_type: input
|
||||
# 31631 - 30001 = 1630
|
||||
address: 1630
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Furnace Temperature
|
||||
unique_id: modbus_pe1_furnace_temperature
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 0
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Calculated Heater Target Temperature
|
||||
unique_id: modbus_pe1_calculated_heater_target_temperature
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 27
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Return Flow Temperature
|
||||
unique_id: modbus_pe1_return_flow_temperature
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 9
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Calculated Target Return Flow Temperature
|
||||
unique_id: modbus_pe1_calculated_target_return_flow_temperature
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 66
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Target Flow Temperature At Circulation Line
|
||||
unique_id: modbus_pe1_return_flow_temperature_at_circulation_line
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 711
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Outside Temperature
|
||||
unique_id: modbus_pe1_outside_temperature
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 1000
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Flow Temperature Actual
|
||||
unique_id: modbus_pe1_flow_temperature_actual
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 1030
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Flow Temperature Target
|
||||
unique_id: modbus_pe1_flow_temperature_target
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 1031
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Room Temperature
|
||||
unique_id: modbus_pe1_room_temperature
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 1032
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Buffer Temperature Top
|
||||
unique_id: modbus_pe1_buffer_temperature_top
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 2000
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
- name: Modbus PE1 Buffer Temperature Bottom
|
||||
unique_id: modbus_pe1_buffer_temperature_bottom
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 2002
|
||||
scan_interval: 30
|
||||
scale: 0.5
|
||||
precision: 0
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
unit_of_measurement: °C
|
||||
|
||||
# CONSUMPTION
|
||||
- name: Modbus PE1 Total Pellet Consumption
|
||||
unique_id: modbus_pe1_total_pellet_consumption
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 83
|
||||
scan_interval: 3600
|
||||
scale: 0.1
|
||||
precision: 1
|
||||
device_class: weight
|
||||
state_class: total_increasing
|
||||
unit_of_measurement: mg
|
||||
- name: Modbus PE1 Pellet Consumption KG
|
||||
unique_id: modbus_pe1_pellet_consumption_kg
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 81
|
||||
scan_interval: 3600
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: weight
|
||||
state_class: total
|
||||
unit_of_measurement: kg
|
||||
- name: Modbus PE1 Pellet Fill Level
|
||||
unique_id: modbus_pe1_pellet_fill_level
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 21
|
||||
scan_interval: 3600
|
||||
scale: 0.005
|
||||
precision: 1
|
||||
device_class: battery
|
||||
state_class: measurement
|
||||
unit_of_measurement: '%'
|
||||
|
||||
# PUMP CONTROLS
|
||||
- name: Modbus PE1 Return Flow Pump Control
|
||||
unique_id: modbus_pe1_return_flow_pump_control
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 36
|
||||
scan_interval: 30
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: power_factor
|
||||
state_class: measurement
|
||||
unit_of_measurement: '%'
|
||||
- name: Modbus PE1 Water Boiler Pump Control
|
||||
unique_id: modbus_pe1_water_boiler_pump_control
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 1632
|
||||
scan_interval: 30
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: power_factor
|
||||
state_class: measurement
|
||||
unit_of_measurement: '%'
|
||||
- name: Modbus PE1 Buffer Pump Control
|
||||
unique_id: modbus_pe1_buffer_pump_control
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 2003
|
||||
scan_interval: 30
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: power_factor
|
||||
state_class: measurement
|
||||
unit_of_measurement: '%'
|
||||
|
||||
# BUFFER CHARGE
|
||||
- name: Modbus PE1 Buffer Charge
|
||||
unique_id: modbus_pe1_buffer_charge
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 2006
|
||||
scan_interval: 30
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: battery
|
||||
state_class: measurement
|
||||
unit_of_measurement: '%'
|
||||
|
||||
# MISC
|
||||
- name: Modbus PE1 Operating Hours
|
||||
unique_id: modbus_pe1_operating_hours
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 20
|
||||
scan_interval: 3600
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: duration
|
||||
state_class: total_increasing
|
||||
unit_of_measurement: 'h'
|
||||
- name: Modbus PE1 Hours Since Last Maintenance
|
||||
unique_id: modbus_pe1_hours_since_last_maintenance
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 55
|
||||
scan_interval: 3600
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: duration
|
||||
state_class: total
|
||||
unit_of_measurement: 'h'
|
||||
- name: Modbus PE1 Hours Of Pellets Operation
|
||||
unique_id: modbus_pe1_hours_of_pellets_operation
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 62
|
||||
scan_interval: 3600
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: duration
|
||||
state_class: total_increasing
|
||||
unit_of_measurement: 'h'
|
||||
- name: Modbus PE1 Hours Of Heating
|
||||
unique_id: modbus_pe1_hours_of_heating
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 63
|
||||
scan_interval: 3600
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: duration
|
||||
state_class: total_increasing
|
||||
unit_of_measurement: 'h'
|
||||
- name: Modbus PE1 Hours Until Ash Removal
|
||||
unique_id: modbus_pe1_hours_until_ash_removal
|
||||
slave: 2
|
||||
input_type: input
|
||||
address: 86
|
||||
scan_interval: 3600
|
||||
scale: 1
|
||||
precision: 0
|
||||
device_class: duration
|
||||
state_class: measurement
|
||||
unit_of_measurement: 'h'
|
||||
Reference in New Issue