Feature 131 control trv valve (#139)
* Add configFlow and translations * Refacto VersatileThermostat with BaseThermostat. Tests ok * Add ThermostatValve. All tests ok --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -11,16 +11,16 @@ from homeassistant.components.climate import (
|
||||
ClimateEntityFeature,
|
||||
)
|
||||
|
||||
PRESET_AC_SUFFIX = "_ac"
|
||||
PRESET_ECO_AC = PRESET_ECO + PRESET_AC_SUFFIX
|
||||
PRESET_COMFORT_AC = PRESET_COMFORT + PRESET_AC_SUFFIX
|
||||
PRESET_BOOST_AC = PRESET_BOOST + PRESET_AC_SUFFIX
|
||||
|
||||
from homeassistant.exceptions import HomeAssistantError
|
||||
|
||||
from .prop_algorithm import (
|
||||
PROPORTIONAL_FUNCTION_TPI,
|
||||
)
|
||||
PRESET_AC_SUFFIX = "_ac"
|
||||
PRESET_ECO_AC = PRESET_ECO + PRESET_AC_SUFFIX
|
||||
PRESET_COMFORT_AC = PRESET_COMFORT + PRESET_AC_SUFFIX
|
||||
PRESET_BOOST_AC = PRESET_BOOST + PRESET_AC_SUFFIX
|
||||
|
||||
|
||||
DEVICE_MANUFACTURER = "JMCOLLIN"
|
||||
DEVICE_MODEL = "Versatile Thermostat"
|
||||
@@ -65,6 +65,7 @@ CONF_SECURITY_DEFAULT_ON_PERCENT = "security_default_on_percent"
|
||||
CONF_THERMOSTAT_TYPE = "thermostat_type"
|
||||
CONF_THERMOSTAT_SWITCH = "thermostat_over_switch"
|
||||
CONF_THERMOSTAT_CLIMATE = "thermostat_over_climate"
|
||||
CONF_THERMOSTAT_VALVE = "thermostat_over_valve"
|
||||
CONF_CLIMATE = "climate_entity_id"
|
||||
CONF_CLIMATE_2 = "climate_entity2_id"
|
||||
CONF_CLIMATE_3 = "climate_entity3_id"
|
||||
@@ -77,6 +78,10 @@ CONF_AC_MODE = "ac_mode"
|
||||
CONF_WINDOW_AUTO_OPEN_THRESHOLD = "window_auto_open_threshold"
|
||||
CONF_WINDOW_AUTO_CLOSE_THRESHOLD = "window_auto_close_threshold"
|
||||
CONF_WINDOW_AUTO_MAX_DURATION = "window_auto_max_duration"
|
||||
CONF_VALVE = "valve_entity_id"
|
||||
CONF_VALVE_2 = "valve_entity2_id"
|
||||
CONF_VALVE_3 = "valve_entity3_id"
|
||||
CONF_VALVE_4 = "valve_entity4_id"
|
||||
|
||||
CONF_PRESETS = {
|
||||
p: f"{p}_temp"
|
||||
@@ -174,6 +179,11 @@ ALL_CONF = (
|
||||
CONF_USE_PRESENCE_FEATURE,
|
||||
CONF_USE_POWER_FEATURE,
|
||||
CONF_AC_MODE,
|
||||
CONF_VALVE,
|
||||
CONF_VALVE_2,
|
||||
CONF_VALVE_3,
|
||||
CONF_VALVE_4,
|
||||
|
||||
]
|
||||
+ CONF_PRESETS_VALUES
|
||||
+ CONF_PRESETS_AWAY_VALUES
|
||||
@@ -185,7 +195,7 @@ CONF_FUNCTIONS = [
|
||||
PROPORTIONAL_FUNCTION_TPI,
|
||||
]
|
||||
|
||||
CONF_THERMOSTAT_TYPES = [CONF_THERMOSTAT_SWITCH, CONF_THERMOSTAT_CLIMATE]
|
||||
CONF_THERMOSTAT_TYPES = [CONF_THERMOSTAT_SWITCH, CONF_THERMOSTAT_CLIMATE, CONF_THERMOSTAT_VALVE]
|
||||
|
||||
SUPPORT_FLAGS = ClimateEntityFeature.TARGET_TEMPERATURE
|
||||
|
||||
@@ -217,3 +227,14 @@ class UnknownEntity(HomeAssistantError):
|
||||
|
||||
class WindowOpenDetectionMethod(HomeAssistantError):
|
||||
"""Error to indicate there is an error in the window open detection method given."""
|
||||
|
||||
class overrides: # pylint: disable=invalid-name
|
||||
""" An annotation to inform overrides """
|
||||
def __init__(self, func):
|
||||
self.func = func
|
||||
|
||||
def __get__(self, instance, owner):
|
||||
return self.func.__get__(instance, owner)
|
||||
|
||||
def __call__(self, *args, **kwargs):
|
||||
raise RuntimeError(f"Method {self.func.__name__} should have been overridden")
|
||||
|
||||
Reference in New Issue
Block a user