From d96fe4bec79ec4827f24491adfadfecf871a4313 Mon Sep 17 00:00:00 2001 From: Jean-Marc Collin Date: Sat, 30 Mar 2024 07:51:22 +0000 Subject: [PATCH] Add Nodon module virtuak switch example --- README-fr.md | 38 ++++++++++++++++++++++++++++++++++++++ README.md | 38 ++++++++++++++++++++++++++++++++++++++ 2 files changed, 76 insertions(+) diff --git a/README-fr.md b/README-fr.md index 1e97679..a5b0f0c 100644 --- a/README-fr.md +++ b/README-fr.md @@ -75,6 +75,7 @@ - [Dépannages](#dépannages) - [Utilisation d'un Heatzy](#utilisation-dun-heatzy) - [Utilisation d'un radiateur avec un fil pilote](#utilisation-dun-radiateur-avec-un-fil-pilote) + - [Utilisation d'un radiateur avec un fil pilote](#utilisation-dun-radiateur-avec-un-fil-pilote-1) - [Seul le premier radiateur chauffe](#seul-le-premier-radiateur-chauffe) - [Le radiateur chauffe alors que la température de consigne est dépassée ou ne chauffe pas alors que la température de la pièce est bien en-dessous de la consigne](#le-radiateur-chauffe-alors-que-la-température-de-consigne-est-dépassée-ou-ne-chauffe-pas-alors-que-la-température-de-la-pièce-est-bien-en-dessous-de-la-consigne) - [Type `over_switch` ou `over_valve`](#type-over_switch-ou-over_valve) @@ -1497,6 +1498,43 @@ Exemple : +
+Utilisation d'un radiateur avec un module Nodon + +## Utilisation d'un radiateur avec un fil pilote +Comme pour le Heatzy ci-dessus vous pouvez utiliser un switch virtuel qui va changer le preset de votre radiateur en fonction de l'état d'allumage du VTherm. +Exemple : +``` +- platform: template + switches: + chauffage_chb_parents: + unique_id: chauffage_chb_parents + friendly_name: Chauffage chambre parents + value_template: "{{ is_state('select.fp_chb_parents_pilot_wire_mode', 'comfort') }}" + icon_template: >- + {% if is_state('select.fp_chb_parents_pilot_wire_mode', 'comfort') %} + mdi:radiator + {% elif is_state('select.fp_chb_parents_pilot_wire_mode', 'frost_protection') %} + mdi:snowflake + {% else %} + mdi:radiator-disabled + {% endif %} + turn_on: + service: select.select_option + target: + entity_id: select.fp_chb_parents_pilot_wire_mode + data: + option: comfort + turn_off: + service: select.select_option + target: + entity_id: select.fp_chb_parents_pilot_wire_mode + data: + option: eco +``` + +
+
Seul le premier radiateur chauffe diff --git a/README.md b/README.md index 7b36bbc..ba1cc38 100644 --- a/README.md +++ b/README.md @@ -76,6 +76,7 @@ - [Troubleshooting](#troubleshooting) - [Using a Heatzy](#using-a-heatzy) - [Using a Heatsink with a Pilot Wire](#using-a-heatsink-with-a-pilot-wire) + - [Using a heater with a Nodon module](#using-a-heater-with-a-nodon-module) - [Only the first radiator heats](#only-the-first-radiator-heats) - [The radiator heats up even though the setpoint temperature is exceeded or does not heat up even though the room temperature is well below the setpoint](#the-radiator-heats-up-even-though-the-setpoint-temperature-is-exceeded-or-does-not-heat-up-even-though-the-room-temperature-is-well-below-the-setpoint) - [Type `over_switch` or `over_valve`](#type-over_switch-or-over_valve) @@ -1488,6 +1489,43 @@ Example : ```
+
+Using a heater with a Nodon + +## Using a heater with a Nodon module +As for the heatzy module above you can use a virtual switch which will change the preset of your heater depending of the state of the VTherm. +Example : +``` +- platform: template + switches: + chauffage_chb_parents: + unique_id: chauffage_chb_parents + friendly_name: Chauffage chambre parents + value_template: "{{ is_state('select.fp_chb_parents_pilot_wire_mode', 'comfort') }}" + icon_template: >- + {% if is_state('select.fp_chb_parents_pilot_wire_mode', 'comfort') %} + mdi:radiator + {% elif is_state('select.fp_chb_parents_pilot_wire_mode', 'frost_protection') %} + mdi:snowflake + {% else %} + mdi:radiator-disabled + {% endif %} + turn_on: + service: select.select_option + target: + entity_id: select.fp_chb_parents_pilot_wire_mode + data: + option: comfort + turn_off: + service: select.select_option + target: + entity_id: select.fp_chb_parents_pilot_wire_mode + data: + option: eco +``` + +
+
Only the first radiator heats