22b2b965c1
* First implem + tests (not finished) * With tests of calculate_shedding ok * Commit for rebase * All tests ok for central_feature_power_manager * All tests not ok * All tests ok * integrattion tests - Do startup works * enhance the overpowering algo if current_power > max_power * Change shedding calculation delay to 20 sec (vs 60 sec) * Integration tests ok * Fix overpowering is set even if other heater have on_percent = 0 * Fix too much shedding in over_climate * Add logs * Add temporal filter for calculate_shedding Add restore overpowering state at startup * Fix restore overpowering_state * Removes poweer_entity_id from vtherm non central config * Release * Add Sonoff TRVZB in creation.md * Add comment on Sonoff TRVZB Closing degree --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
310 lines
12 KiB
Python
310 lines
12 KiB
Python
""" Implements a central Power Feature Manager for Versatile Thermostat """
|
|
|
|
import logging
|
|
from typing import Any
|
|
from functools import cmp_to_key
|
|
|
|
from datetime import timedelta
|
|
|
|
from homeassistant.const import STATE_OFF
|
|
from homeassistant.core import HomeAssistant, Event, callback
|
|
from homeassistant.helpers.event import (
|
|
async_track_state_change_event,
|
|
EventStateChangedData,
|
|
async_call_later,
|
|
)
|
|
from homeassistant.helpers.entity_component import EntityComponent
|
|
from homeassistant.components.climate import (
|
|
ClimateEntity,
|
|
DOMAIN as CLIMATE_DOMAIN,
|
|
)
|
|
|
|
|
|
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
|
|
from .commons import ConfigData
|
|
from .base_manager import BaseFeatureManager
|
|
|
|
# circular dependency
|
|
# from .base_thermostat import BaseThermostat
|
|
|
|
MIN_DTEMP_SECS = 20
|
|
|
|
_LOGGER = logging.getLogger(__name__)
|
|
|
|
|
|
class CentralFeaturePowerManager(BaseFeatureManager):
|
|
"""A central Power feature manager"""
|
|
|
|
def __init__(self, hass: HomeAssistant, vtherm_api: Any):
|
|
"""Init of a featureManager"""
|
|
super().__init__(None, hass, "centralPowerManager")
|
|
self._hass: HomeAssistant = hass
|
|
self._vtherm_api = vtherm_api # no type due to circular reference
|
|
self._is_configured: bool = False
|
|
self._power_sensor_entity_id: str = None
|
|
self._max_power_sensor_entity_id: str = None
|
|
self._current_power: float = None
|
|
self._current_max_power: float = None
|
|
self._power_temp: float = None
|
|
self._cancel_calculate_shedding_call = None
|
|
# Not used now
|
|
self._last_shedding_date = None
|
|
|
|
def post_init(self, entry_infos: ConfigData):
|
|
"""Gets the configuration parameters"""
|
|
central_config = self._vtherm_api.find_central_configuration()
|
|
if not central_config:
|
|
_LOGGER.info("No central configuration is found. Power management will be deactivated")
|
|
return
|
|
|
|
self._power_sensor_entity_id = entry_infos.get(CONF_POWER_SENSOR)
|
|
self._max_power_sensor_entity_id = entry_infos.get(CONF_MAX_POWER_SENSOR)
|
|
self._power_temp = entry_infos.get(CONF_PRESET_POWER)
|
|
|
|
self._is_configured = False
|
|
self._current_power = None
|
|
self._current_max_power = None
|
|
if (
|
|
entry_infos.get(CONF_USE_POWER_FEATURE, False)
|
|
and self._max_power_sensor_entity_id
|
|
and self._power_sensor_entity_id
|
|
and self._power_temp
|
|
):
|
|
self._is_configured = True
|
|
else:
|
|
_LOGGER.info("Power management is not fully configured and will be deactivated")
|
|
|
|
async def start_listening(self):
|
|
"""Start listening the power sensor"""
|
|
if not self._is_configured:
|
|
return
|
|
|
|
self.stop_listening()
|
|
|
|
self.add_listener(
|
|
async_track_state_change_event(
|
|
self.hass,
|
|
[self._power_sensor_entity_id],
|
|
self._power_sensor_changed,
|
|
)
|
|
)
|
|
|
|
self.add_listener(
|
|
async_track_state_change_event(
|
|
self.hass,
|
|
[self._max_power_sensor_entity_id],
|
|
self._max_power_sensor_changed,
|
|
)
|
|
)
|
|
|
|
@callback
|
|
async def _power_sensor_changed(self, event: Event[EventStateChangedData]):
|
|
"""Handle power changes."""
|
|
_LOGGER.debug("Receive new Power event")
|
|
_LOGGER.debug(event)
|
|
await self.refresh_state()
|
|
|
|
@callback
|
|
async def _max_power_sensor_changed(self, event: Event[EventStateChangedData]):
|
|
"""Handle power max changes."""
|
|
_LOGGER.debug("Receive new Power Max event")
|
|
_LOGGER.debug(event)
|
|
await self.refresh_state()
|
|
|
|
@overrides
|
|
async def refresh_state(self) -> bool:
|
|
"""Tries to get the last state from sensor
|
|
Returns True if a change has been made"""
|
|
|
|
async def _calculate_shedding_internal(_):
|
|
_LOGGER.debug("Do the shedding calculation")
|
|
await self.calculate_shedding()
|
|
if self._cancel_calculate_shedding_call:
|
|
self._cancel_calculate_shedding_call()
|
|
self._cancel_calculate_shedding_call = None
|
|
|
|
if not self._is_configured:
|
|
return False
|
|
|
|
# Retrieve current power
|
|
new_power = get_safe_float(self._hass, self._power_sensor_entity_id)
|
|
power_changed = new_power is not None and self._current_power != new_power
|
|
if power_changed:
|
|
self._current_power = new_power
|
|
_LOGGER.debug("New current power has been retrieved: %.3f", self._current_power)
|
|
|
|
# Retrieve max power
|
|
new_max_power = get_safe_float(self._hass, self._max_power_sensor_entity_id)
|
|
max_power_changed = new_max_power is not None and self._current_max_power != new_max_power
|
|
if max_power_changed:
|
|
self._current_max_power = new_max_power
|
|
_LOGGER.debug("New current max power has been retrieved: %.3f", self._current_max_power)
|
|
|
|
# Schedule shedding calculation if there's any change
|
|
if power_changed or max_power_changed:
|
|
if not self._cancel_calculate_shedding_call:
|
|
self._cancel_calculate_shedding_call = async_call_later(self.hass, timedelta(seconds=MIN_DTEMP_SECS), _calculate_shedding_internal)
|
|
return True
|
|
|
|
return False
|
|
|
|
# For testing purpose only, do an immediate shedding calculation
|
|
async def _do_immediate_shedding(self):
|
|
"""Do an immmediate shedding calculation if a timer was programmed.
|
|
Else, do nothing"""
|
|
if self._cancel_calculate_shedding_call:
|
|
self._cancel_calculate_shedding_call()
|
|
self._cancel_calculate_shedding_call = None
|
|
await self.calculate_shedding()
|
|
|
|
async def calculate_shedding(self):
|
|
"""Do the shedding calculation and set/unset VTherm into overpowering state"""
|
|
if not self.is_configured or self.current_max_power is None or self.current_power is None:
|
|
return
|
|
|
|
_LOGGER.debug("-------- Start of calculate_shedding")
|
|
# Find all VTherms
|
|
available_power = self.current_max_power - self.current_power
|
|
vtherms_sorted = self.find_all_vtherm_with_power_management_sorted_by_dtemp()
|
|
|
|
# shedding only
|
|
if available_power < 0:
|
|
_LOGGER.debug(
|
|
"The available power is is < 0 (%s). Set overpowering only for list: %s",
|
|
available_power,
|
|
vtherms_sorted,
|
|
)
|
|
# we will set overpowering for the nearest target temp first
|
|
total_power_gain = 0
|
|
|
|
for vtherm in vtherms_sorted:
|
|
if vtherm.is_device_active and not vtherm.power_manager.is_overpowering_detected:
|
|
device_power = vtherm.power_manager.device_power
|
|
total_power_gain += device_power
|
|
_LOGGER.info("vtherm %s should be in overpowering state (device_power=%.2f)", vtherm.name, device_power)
|
|
await vtherm.power_manager.set_overpowering(True, device_power)
|
|
|
|
_LOGGER.debug("after vtherm %s total_power_gain=%s, available_power=%s", vtherm.name, total_power_gain, available_power)
|
|
if total_power_gain >= -available_power:
|
|
_LOGGER.debug("We have found enough vtherm to set to overpowering")
|
|
break
|
|
# unshedding only
|
|
else:
|
|
vtherms_sorted.reverse()
|
|
_LOGGER.debug("The available power is is > 0 (%s). Do a complete shedding/un-shedding calculation for list: %s", available_power, vtherms_sorted)
|
|
|
|
total_power_added = 0
|
|
|
|
for vtherm in vtherms_sorted:
|
|
# We want to do always unshedding in order to initialize the state
|
|
# so we cannot use is_overpowering_detected which test also UNKNOWN and UNAVAILABLE
|
|
if vtherm.power_manager.overpowering_state == STATE_OFF:
|
|
continue
|
|
|
|
power_consumption_max = device_power = vtherm.power_manager.device_power
|
|
# calculate the power_consumption_max
|
|
if vtherm.on_percent is not None:
|
|
power_consumption_max = max(
|
|
device_power / vtherm.nb_underlying_entities,
|
|
device_power * vtherm.on_percent,
|
|
)
|
|
|
|
_LOGGER.debug("vtherm %s power_consumption_max is %s (device_power=%s, overclimate=%s)", vtherm.name, power_consumption_max, device_power, vtherm.is_over_climate)
|
|
|
|
# or not ... is for initializing the overpowering state if not already done
|
|
if total_power_added + power_consumption_max < available_power or not vtherm.power_manager.is_overpowering_detected:
|
|
# we count the unshedding only if the VTherm was in shedding
|
|
if vtherm.power_manager.is_overpowering_detected:
|
|
_LOGGER.info("vtherm %s should not be in overpowering state (power_consumption_max=%.2f)", vtherm.name, power_consumption_max)
|
|
total_power_added += power_consumption_max
|
|
|
|
await vtherm.power_manager.set_overpowering(False)
|
|
|
|
if total_power_added >= available_power:
|
|
_LOGGER.debug("We have found enough vtherm to set to non-overpowering")
|
|
break
|
|
|
|
_LOGGER.debug("after vtherm %s total_power_added=%s, available_power=%s", vtherm.name, total_power_added, available_power)
|
|
|
|
self._last_shedding_date = self._vtherm_api.now
|
|
_LOGGER.debug("-------- End of calculate_shedding")
|
|
|
|
def get_climate_components_entities(self) -> list:
|
|
"""Get all VTherms entitites"""
|
|
vtherms = []
|
|
component: EntityComponent[ClimateEntity] = self._hass.data.get(
|
|
CLIMATE_DOMAIN, None
|
|
)
|
|
if component:
|
|
for entity in component.entities:
|
|
# A little hack to test if the climate is a VTherm. Cannot use isinstance
|
|
# due to circular dependency of BaseThermostat
|
|
if (
|
|
entity.device_info
|
|
and entity.device_info.get("model", None) == DOMAIN
|
|
):
|
|
vtherms.append(entity)
|
|
return vtherms
|
|
|
|
def find_all_vtherm_with_power_management_sorted_by_dtemp(
|
|
self,
|
|
) -> list:
|
|
"""Returns all the VTherms with power management activated"""
|
|
entities = self.get_climate_components_entities()
|
|
vtherms = [
|
|
vtherm
|
|
for vtherm in entities
|
|
if vtherm.power_manager.is_configured and vtherm.is_on
|
|
]
|
|
|
|
# sort the result with the min temp difference first. A and B should be BaseThermostat class
|
|
def cmp_temps(a, b) -> int:
|
|
diff_a = float("inf")
|
|
diff_b = float("inf")
|
|
a_target = a.target_temperature if not a.power_manager.is_overpowering_detected else a.saved_target_temp
|
|
b_target = b.target_temperature if not b.power_manager.is_overpowering_detected else b.saved_target_temp
|
|
if a.current_temperature is not None and a_target is not None:
|
|
diff_a = a_target - a.current_temperature
|
|
if b.current_temperature is not None and b_target is not None:
|
|
diff_b = b_target - b.current_temperature
|
|
|
|
if diff_a == diff_b:
|
|
return 0
|
|
return 1 if diff_a > diff_b else -1
|
|
|
|
vtherms.sort(key=cmp_to_key(cmp_temps))
|
|
return vtherms
|
|
|
|
@property
|
|
def is_configured(self) -> bool:
|
|
"""True if the FeatureManager is fully configured"""
|
|
return self._is_configured
|
|
|
|
@property
|
|
def current_power(self) -> float | None:
|
|
"""Return the current power from sensor"""
|
|
return self._current_power
|
|
|
|
@property
|
|
def current_max_power(self) -> float | None:
|
|
"""Return the current power from sensor"""
|
|
return self._current_max_power
|
|
|
|
@property
|
|
def power_temperature(self) -> float | None:
|
|
"""Return the power temperature"""
|
|
return self._power_temp
|
|
|
|
@property
|
|
def power_sensor_entity_id(self) -> float | None:
|
|
"""Return the power sensor entity id"""
|
|
return self._power_sensor_entity_id
|
|
|
|
@property
|
|
def max_power_sensor_entity_id(self) -> float | None:
|
|
"""Return the max power sensor entity id"""
|
|
return self._max_power_sensor_entity_id
|
|
|
|
def __str__(self):
|
|