@@ -1582,6 +1582,8 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
if not new_state:
|
||||
return
|
||||
|
||||
new_hvac_mode = new_state.state
|
||||
|
||||
old_state = event.data.get("old_state")
|
||||
old_hvac_action = (
|
||||
old_state.attributes.get("hvac_action")
|
||||
@@ -1594,16 +1596,21 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
else None
|
||||
)
|
||||
|
||||
# Issue 99 - some AC turn hvac_mode=cool and hvac_action=idle when sending a HVACMode_OFF command
|
||||
if self._hvac_mode == HVACMode.OFF and new_hvac_action == HVACAction.IDLE:
|
||||
_LOGGER.debug("The underlying switch to idle instead of OFF. We will consider it as OFF")
|
||||
new_hvac_mode = HVACMode.OFF
|
||||
|
||||
_LOGGER.info(
|
||||
"%s - Underlying climate changed. Event.new_state is %s, current_hvac_mode=%s, new_hvac_action=%s, old_hvac_action=%s",
|
||||
"%s - Underlying climate changed. Event.new_hvac_mode is %s, current_hvac_mode=%s, new_hvac_action=%s, old_hvac_action=%s",
|
||||
self,
|
||||
new_state,
|
||||
new_hvac_mode,
|
||||
self._hvac_mode,
|
||||
new_hvac_action,
|
||||
old_hvac_action,
|
||||
)
|
||||
|
||||
if new_state.state in [
|
||||
if new_hvac_mode in [
|
||||
HVACMode.OFF,
|
||||
HVACMode.HEAT,
|
||||
HVACMode.COOL,
|
||||
@@ -1613,7 +1620,7 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
HVACMode.FAN_ONLY,
|
||||
None
|
||||
]:
|
||||
self._hvac_mode = new_state.state
|
||||
self._hvac_mode = new_hvac_mode
|
||||
|
||||
# Interpretation of hvac
|
||||
HVAC_ACTION_ON = [ # pylint: disable=invalid-name
|
||||
|
||||
@@ -1,120 +1,121 @@
|
||||
reload:
|
||||
description: Reload all Versatile Thermostat entities.
|
||||
name: Reload
|
||||
description: Reload all Versatile Thermostat entities.
|
||||
|
||||
set_presence:
|
||||
name: Set presence
|
||||
description: Force the presence mode in thermostat
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
presence:
|
||||
name: Presence
|
||||
description: Presence setting
|
||||
required: true
|
||||
advanced: false
|
||||
example: "on"
|
||||
default: "on"
|
||||
selector:
|
||||
select:
|
||||
options:
|
||||
- "on"
|
||||
- "off"
|
||||
- "home"
|
||||
- "not_home"
|
||||
name: Set presence
|
||||
description: Force the presence mode in thermostat
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
presence:
|
||||
name: Presence
|
||||
description: Presence setting
|
||||
required: true
|
||||
advanced: false
|
||||
example: "on"
|
||||
default: "on"
|
||||
selector:
|
||||
select:
|
||||
options:
|
||||
- "on"
|
||||
- "off"
|
||||
- "home"
|
||||
- "not_home"
|
||||
|
||||
set_preset_temperature:
|
||||
name: Set temperature preset
|
||||
description: Change the target temperature of a preset
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
preset:
|
||||
name: Preset
|
||||
description: Preset name
|
||||
required: true
|
||||
advanced: false
|
||||
example: "comfort"
|
||||
selector:
|
||||
select:
|
||||
options:
|
||||
- "eco"
|
||||
- "comfort"
|
||||
- "boost"
|
||||
temperature:
|
||||
name: Temperature when present
|
||||
description: Target temperature for the preset when present
|
||||
required: false
|
||||
advanced: false
|
||||
example: "19.5"
|
||||
default: "17"
|
||||
selector:
|
||||
number:
|
||||
min: 7
|
||||
max: 35
|
||||
step: 0.1
|
||||
unit_of_measurement: °
|
||||
mode: slider
|
||||
temperature_away:
|
||||
name: Temperature when not present
|
||||
description: Target temperature for the preset when not present
|
||||
required: false
|
||||
advanced: false
|
||||
example: "17"
|
||||
default: "15"
|
||||
selector:
|
||||
number:
|
||||
min: 7
|
||||
max: 35
|
||||
step: 0.1
|
||||
unit_of_measurement: °
|
||||
mode: slider
|
||||
name: Set temperature preset
|
||||
description: Change the target temperature of a preset
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
preset:
|
||||
name: Preset
|
||||
description: Preset name
|
||||
required: true
|
||||
advanced: false
|
||||
example: "comfort"
|
||||
selector:
|
||||
select:
|
||||
options:
|
||||
- "eco"
|
||||
- "comfort"
|
||||
- "boost"
|
||||
temperature:
|
||||
name: Temperature when present
|
||||
description: Target temperature for the preset when present
|
||||
required: false
|
||||
advanced: false
|
||||
example: "19.5"
|
||||
default: "17"
|
||||
selector:
|
||||
number:
|
||||
min: 7
|
||||
max: 35
|
||||
step: 0.1
|
||||
unit_of_measurement: °
|
||||
mode: slider
|
||||
temperature_away:
|
||||
name: Temperature when not present
|
||||
description: Target temperature for the preset when not present
|
||||
required: false
|
||||
advanced: false
|
||||
example: "17"
|
||||
default: "15"
|
||||
selector:
|
||||
number:
|
||||
min: 7
|
||||
max: 35
|
||||
step: 0.1
|
||||
unit_of_measurement: °
|
||||
mode: slider
|
||||
|
||||
set_security:
|
||||
name: Set security
|
||||
description: Change the security parameters
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
delay_min:
|
||||
name: Delay in minutes
|
||||
description: Maximum allowed delay in minutes between two temperature mesures
|
||||
required: false
|
||||
advanced: false
|
||||
example: "30"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 9999
|
||||
unit_of_measurement: "min"
|
||||
mode: box
|
||||
min_on_percent:
|
||||
name: Minimal on_percent
|
||||
description: Minimal heating percent value for security preset activation
|
||||
required: false
|
||||
advanced: false
|
||||
example: "0.5"
|
||||
default: "0.5"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 1
|
||||
step: 0.05
|
||||
unit_of_measurement: "%"
|
||||
mode: slider
|
||||
default_on_percent:
|
||||
name: on_percent used in security mode
|
||||
description: The default heating percent value in security preset
|
||||
required: false
|
||||
advanced: false
|
||||
example: "0.1"
|
||||
default: "0.1"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 1
|
||||
step: 0.05
|
||||
unit_of_measurement: "%"
|
||||
mode: slider
|
||||
name: Set security
|
||||
description: Change the security parameters
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
delay_min:
|
||||
name: Delay in minutes
|
||||
description: Maximum allowed delay in minutes between two temperature mesures
|
||||
required: false
|
||||
advanced: false
|
||||
example: "30"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 9999
|
||||
unit_of_measurement: "min"
|
||||
mode: box
|
||||
min_on_percent:
|
||||
name: Minimal on_percent
|
||||
description: Minimal heating percent value for security preset activation
|
||||
required: false
|
||||
advanced: false
|
||||
example: "0.5"
|
||||
default: "0.5"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 1
|
||||
step: 0.05
|
||||
unit_of_measurement: "%"
|
||||
mode: slider
|
||||
default_on_percent:
|
||||
name: on_percent used in security mode
|
||||
description: The default heating percent value in security preset
|
||||
required: false
|
||||
advanced: false
|
||||
example: "0.1"
|
||||
default: "0.1"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 1
|
||||
step: 0.05
|
||||
unit_of_measurement: "%"
|
||||
mode: slider
|
||||
|
||||
Reference in New Issue