Jean-Marc Collin 668053b352 Fix unit_test 2024-10-07 05:22:57 +00:00
Jean-Marc Collin 6ff9ff1ee5 Fix variables in error log 2024-10-07 04:52:33 +00:00
Jean-Marc Collin 3f95ed74f4 FIX TypeError: '>' not supported between instances of 'float' and 'NoneType' error message 2024-10-06 09:04:47 +00:00
Jean-Marc Collin 6e42904ddf Issue #518 - Fix ThermostatOverClimate object has no attribute __attr_preset_modes 2024-10-06 08:58:58 +00:00
Jean-Marc Collin 4c1fc396fb Issue #500 - check feature is use central config is checked (#513)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-09-29 11:34:39 +02:00
4 changed files with 115 additions and 26 deletions
@@ -13,7 +13,6 @@ from homeassistant.util import dt as dt_util
from homeassistant.core import (
HomeAssistant,
callback,
CoreState,
Event,
State,
)
@@ -57,7 +56,6 @@ from homeassistant.const import (
STATE_UNKNOWN,
STATE_OFF,
STATE_ON,
EVENT_HOMEASSISTANT_START,
STATE_HOME,
STATE_NOT_HOME,
)
@@ -299,7 +297,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
self._presets: dict[str, Any] = {} # presets
self._presets_away: dict[str, Any] = {} # presets_away
self._attr_preset_modes: list[str] | None
self._attr_preset_modes: list[str] = []
self._use_central_config_temperature = False
@@ -2183,7 +2181,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
new_central_mode,
)
first_init = self._last_central_mode == None
first_init = self._last_central_mode is None
self._last_central_mode = new_central_mode
@@ -99,30 +99,31 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
def _init_feature_flags(self, _):
"""Fix features selection depending to infos"""
is_empty: bool = False # TODO remove this not bool(infos)
is_central_config = (
self._infos.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_CENTRAL_CONFIG
)
self._infos[CONF_USE_WINDOW_FEATURE] = (
is_empty
self._infos.get(CONF_USE_WINDOW_CENTRAL_CONFIG)
or self._infos.get(CONF_WINDOW_SENSOR) is not None
or self._infos.get(CONF_WINDOW_AUTO_OPEN_THRESHOLD) is not None
)
self._infos[CONF_USE_MOTION_FEATURE] = (
is_empty
or self._infos.get(CONF_MOTION_SENSOR) is not None
or is_central_config
)
self._infos[CONF_USE_POWER_FEATURE] = is_empty or (
self._infos[CONF_USE_MOTION_FEATURE] = self._infos.get(
CONF_USE_MOTION_FEATURE
) and (self._infos.get(CONF_MOTION_SENSOR) is not None or is_central_config)
self._infos[CONF_USE_POWER_FEATURE] = self._infos.get(
CONF_USE_POWER_CENTRAL_CONFIG
) or (
self._infos.get(CONF_POWER_SENSOR) is not None
and self._infos.get(CONF_MAX_POWER_SENSOR) is not None
)
self._infos[CONF_USE_PRESENCE_FEATURE] = (
is_empty or self._infos.get(CONF_PRESENCE_SENSOR) is not None
self._infos.get(CONF_USE_PRESENCE_CENTRAL_CONFIG)
or self._infos.get(CONF_PRESENCE_SENSOR) is not None
)
self._infos[CONF_USE_CENTRAL_BOILER_FEATURE] = is_empty or (
self._infos[CONF_USE_CENTRAL_BOILER_FEATURE] = (
self._infos.get(CONF_CENTRAL_BOILER_ACTIVATION_SRV) is not None
and self._infos.get(CONF_CENTRAL_BOILER_DEACTIVATION_SRV) is not None
)
@@ -142,7 +142,17 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
"""Sends the regulated temperature to all underlying"""
if self.hvac_mode == HVACMode.OFF:
_LOGGER.debug("%s - don't send regulated temperature cause VTherm is off ")
_LOGGER.debug(
"%s - don't send regulated temperature cause VTherm is off ", self
)
return
if self.target_temperature is None:
_LOGGER.warning(
"%s - don't send regulated temperature cause VTherm target_temp (%s) is None. This should be a temporary warning message.",
self,
self.target_temperature,
)
return
_LOGGER.info(
@@ -169,16 +179,17 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
# use _attr_target_temperature_step to round value if _auto_regulation_dtemp is equal to 0
regulation_step = self._auto_regulation_dtemp if self._auto_regulation_dtemp else self._attr_target_temperature_step
_LOGGER.debug("%s - usage of regulation_step: %.2f ",
self,
regulation_step)
new_regulated_temp = round_to_nearest(
self._regulation_algo.calculate_regulated_temperature(
self.current_temperature, self._cur_ext_temp
),
regulation_step,
)
_LOGGER.debug("%s - usage regulation_step: %.2f ", self, regulation_step)
if self.current_temperature is not None:
new_regulated_temp = round_to_nearest(
self._regulation_algo.calculate_regulated_temperature(
self.current_temperature, self._cur_ext_temp
),
regulation_step,
)
else:
new_regulated_temp = self.target_temperature
dtemp = new_regulated_temp - self._regulated_target_temp
if not force and abs(dtemp) < self._auto_regulation_dtemp:
@@ -203,8 +214,10 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
offset_temp = 0
device_temp = 0
if (
# current_temperature is set
self.current_temperature is not None
# regulation can use the device_temp
self.auto_regulation_use_device_temp
and self.auto_regulation_use_device_temp
# and we have access to the device temp
and (device_temp := under.underlying_current_temperature) is not None
# and target is not reach (ie we need regulation)
+77
View File
@@ -12,6 +12,14 @@ from homeassistant.components.climate import (
SERVICE_SET_TEMPERATURE,
)
from custom_components.versatile_thermostat.config_flow import (
VersatileThermostatBaseConfigFlow,
)
from custom_components.versatile_thermostat.thermostat_valve import ThermostatOverValve
from custom_components.versatile_thermostat.thermostat_switch import (
ThermostatOverSwitch,
)
from .commons import *
logging.getLogger().setLevel(logging.DEBUG)
@@ -1013,3 +1021,72 @@ async def test_bug_508(
),
]
)
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_500_1(hass: HomeAssistant, init_vtherm_api) -> None:
"""Test that the form is served with no input"""
config = {
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_USE_WINDOW_CENTRAL_CONFIG: True,
CONF_USE_POWER_CENTRAL_CONFIG: True,
CONF_USE_PRESENCE_CENTRAL_CONFIG: True,
CONF_USE_MOTION_FEATURE: True,
CONF_MOTION_SENSOR: "sensor.theMotionSensor",
}
flow = VersatileThermostatBaseConfigFlow(config)
assert flow._infos[CONF_USE_WINDOW_FEATURE] is True
assert flow._infos[CONF_USE_POWER_FEATURE] is True
assert flow._infos[CONF_USE_PRESENCE_FEATURE] is True
assert flow._infos[CONF_USE_MOTION_FEATURE] is True
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_500_2(hass: HomeAssistant, init_vtherm_api) -> None:
"""Test that the form is served with no input"""
config = {
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_USE_WINDOW_CENTRAL_CONFIG: False,
CONF_USE_POWER_CENTRAL_CONFIG: False,
CONF_USE_PRESENCE_CENTRAL_CONFIG: False,
CONF_USE_MOTION_FEATURE: False,
}
flow = VersatileThermostatBaseConfigFlow(config)
assert flow._infos[CONF_USE_WINDOW_FEATURE] is False
assert flow._infos[CONF_USE_POWER_FEATURE] is False
assert flow._infos[CONF_USE_PRESENCE_FEATURE] is False
assert flow._infos[CONF_USE_MOTION_FEATURE] is False
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_500_3(hass: HomeAssistant, init_vtherm_api) -> None:
"""Test that the form is served with no input"""
config = {
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_USE_WINDOW_CENTRAL_CONFIG: False,
CONF_WINDOW_SENSOR: "sensor.theWindowSensor",
CONF_USE_POWER_CENTRAL_CONFIG: False,
CONF_POWER_SENSOR: "sensor.thePowerSensor",
CONF_MAX_POWER_SENSOR: "sensor.theMaxPowerSensor",
CONF_USE_PRESENCE_CENTRAL_CONFIG: False,
CONF_PRESENCE_SENSOR: "sensor.thePresenceSensor",
CONF_USE_MOTION_FEATURE: True, # motion sensor need to be checked AND a motion sensor set
CONF_MOTION_SENSOR: "sensor.theMotionSensor",
}
flow = VersatileThermostatBaseConfigFlow(config)
assert flow._infos[CONF_USE_WINDOW_FEATURE] is True
assert flow._infos[CONF_USE_POWER_FEATURE] is True
assert flow._infos[CONF_USE_PRESENCE_FEATURE] is True
assert flow._infos[CONF_USE_MOTION_FEATURE] is True