Compare commits

...

5 Commits

Author SHA1 Message Date
Jean-Marc Collin f9df925181 Issue #615 - VTherm switch to manual on its own (#618)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-11-09 18:44:13 +01:00
Jean-Marc Collin 2d72efe447 Issue 600 energy can be negative after configuration (#614)
* Add logs to diagnose the case

* Issue #552 (#608)

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>

* Fix typo (#607)

* - Force writing state when entity is removed
- Fix bug with issue #552 on CONF_USE_CENTRAL_BOILER_FEATURE which should be proposed on a central configuration
- Improve reload of entity to avoid reloading all VTherm. Only the reconfigured one will be reloaded

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
Co-authored-by: Ludovic BOUÉ <lboue@users.noreply.github.com>
2024-11-07 21:57:08 +01:00
Ludovic BOUÉ 95af6eba97 Fix typo (#607) 2024-11-05 22:47:42 +01:00
Jean-Marc Collin 06dc537767 Issue #552 (#608)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-11-05 22:39:26 +01:00
Joeri Colman 2d79d961dc Update en.json (#604)
fixed typo
2024-11-05 10:40:49 +01:00
14 changed files with 778 additions and 324 deletions
+1
View File
@@ -152,6 +152,7 @@ climate:
name: Underlying thermostat2
heater: input_boolean.fake_heater_switch3
target_sensor: input_number.fake_temperature_sensor1
ac_mode: false
- platform: generic_thermostat
name: Underlying thermostat3
heater: input_boolean.fake_heater_switch3
+1 -1
View File
@@ -1353,7 +1353,7 @@ Example of graph obtained with Plotly :
## And always better and better with the NOTIFIER daemon app to notify events
This automation uses the excellent App Daemon named NOTIFIER developed by Horizon Domotique that you will find in demonstration [here](https://www.youtube.com/watch?v=chJylIK0ASo&ab_channel=HorizonDomotique) and the code is [here](https ://github.com/jlpouffier/home-assistant-config/blob/master/appdaemon/apps/notifier.py). It allows you to notify the users of the accommodation when one of the events affecting safety occurs on one of the Versatile Thermostats.
This automation uses the excellent App Daemon named NOTIFIER developed by Horizon Domotique that you will find in demonstration [here](https://www.youtube.com/watch?v=chJylIK0ASo&ab_channel=HorizonDomotique) and the code is [here](https://github.com/jlpouffier/home-assistant-config/blob/master/appdaemon/apps/notifier.py). It allows you to notify the users of the accommodation when one of the events affecting safety occurs on one of the Versatile Thermostats.
This is a great example of using the notifications described here [notification](#notifications).
@@ -178,13 +178,20 @@ async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
if hass.state == CoreState.running:
await api.reload_central_boiler_entities_list()
await api.init_vtherm_links()
await api.init_vtherm_links(entry.entry_id)
return True
async def update_listener(hass: HomeAssistant, entry: ConfigEntry) -> None:
"""Update listener."""
_LOGGER.debug(
"Calling update_listener entry: entry_id='%s', value='%s'",
entry.entry_id,
entry.data,
)
if entry.data.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_CENTRAL_CONFIG:
await reload_all_vtherm(hass)
else:
@@ -193,7 +200,7 @@ async def update_listener(hass: HomeAssistant, entry: ConfigEntry) -> None:
api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(hass)
if api is not None:
await api.reload_central_boiler_entities_list()
await api.init_vtherm_links()
await api.init_vtherm_links(entry.entry_id)
async def async_unload_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
@@ -19,7 +19,10 @@ from homeassistant.core import (
)
from homeassistant.components.climate import ClimateEntity
from homeassistant.helpers.restore_state import RestoreEntity
from homeassistant.helpers.restore_state import (
RestoreEntity,
async_get as restore_async_get,
)
from homeassistant.helpers.entity import Entity
from homeassistant.config_entries import ConfigEntry
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
@@ -84,6 +87,10 @@ def get_tz(hass: HomeAssistant):
return dt_util.get_time_zone(hass.config.time_zone)
_LOGGER_ENERGY = logging.getLogger(
"custom_components.versatile_thermostat.energy_debug"
)
class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
"""Representation of a base class for all Versatile Thermostat device."""
@@ -198,6 +205,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
self._attr_translation_key = "versatile_thermostat"
self._total_energy = None
_LOGGER_ENERGY.debug("%s - _init_ resetting energy to None", self)
# because energy of climate is calculated in the thermostat we have to keep that here and not in underlying entity
self._underlying_climate_start_hvac_action_date = None
@@ -470,6 +478,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
self._presence_state = None
self._total_energy = None
_LOGGER_ENERGY.debug("%s - post_init_ resetting energy to None", self)
# Read the parameter from configuration.yaml if it exists
short_ema_params = DEFAULT_SHORT_EMA_PARAMS
@@ -585,14 +594,24 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
# issue 428. Link to others entities will start at link
# await self.async_startup()
async def async_will_remove_from_hass(self):
"""Try to force backup of entity"""
_LOGGER_ENERGY.debug(
"%s - force write before remove. Energy is %s", self, self.total_energy
)
# Force dump in background
await restore_async_get(self.hass).async_dump_states()
def remove_thermostat(self):
"""Called when the thermostat will be removed"""
_LOGGER.info("%s - Removing thermostat", self)
for under in self._underlyings:
under.remove_entity()
async def async_startup(self, central_configuration):
"""Triggered on startup, used to get old state and set internal states accordingly"""
"""Triggered on startup, used to get old state and set internal states accordingly. This is triggered by
VTherm API"""
_LOGGER.debug("%s - Calling async_startup", self)
_LOGGER.debug("%s - Calling async_startup_internal", self)
@@ -804,6 +823,11 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
old_total_energy = old_state.attributes.get(ATTR_TOTAL_ENERGY)
self._total_energy = old_total_energy if old_total_energy is not None else 0
_LOGGER_ENERGY.debug(
"%s - get_my_previous_state restored energy is %s",
self,
self._total_energy,
)
self.restore_specific_previous_state(old_state)
else:
@@ -817,6 +841,11 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
"No previously saved temperature, setting to %s", self._target_temp
)
self._total_energy = 0
_LOGGER_ENERGY.debug(
"%s - get_my_previous_state no previous state energy is %s",
self,
self._total_energy,
)
if not self._hvac_mode:
self._hvac_mode = HVACMode.OFF
@@ -2622,6 +2651,22 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
"hvac_off_reason": self.hvac_off_reason,
}
_LOGGER_ENERGY.debug(
"%s - update_custom_attributes saved energy is %s",
self,
self.total_energy,
)
@overrides
def async_write_ha_state(self):
"""overrides to have log"""
_LOGGER_ENERGY.debug(
"%s - async_write_ha_state written state energy is %s",
self,
self._total_energy,
)
return super().async_write_ha_state()
@callback
def async_registry_entry_updated(self):
"""update the entity if the config entry have been updated
@@ -17,7 +17,6 @@ from .const import DOMAIN, DEVICE_MANUFACTURER, ServiceConfigurationError
_LOGGER = logging.getLogger(__name__)
def get_tz(hass: HomeAssistant):
"""Get the current timezone"""
@@ -109,17 +109,17 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
or self._infos.get(CONF_WINDOW_AUTO_OPEN_THRESHOLD) is not None
)
self._infos[CONF_USE_MOTION_FEATURE] = self._infos.get(
CONF_USE_MOTION_FEATURE
CONF_USE_MOTION_FEATURE, False
) and (self._infos.get(CONF_MOTION_SENSOR) is not None or is_central_config)
self._infos[CONF_USE_POWER_FEATURE] = self._infos.get(
CONF_USE_POWER_CENTRAL_CONFIG
CONF_USE_POWER_CENTRAL_CONFIG, False
) or (
self._infos.get(CONF_POWER_SENSOR) is not None
and self._infos.get(CONF_MAX_POWER_SENSOR) is not None
)
self._infos[CONF_USE_PRESENCE_FEATURE] = (
self._infos.get(CONF_USE_PRESENCE_CENTRAL_CONFIG)
self._infos.get(CONF_USE_PRESENCE_CENTRAL_CONFIG, False)
or self._infos.get(CONF_PRESENCE_SENSOR) is not None
)
@@ -129,7 +129,7 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
)
self._infos[CONF_USE_AUTO_START_STOP_FEATURE] = (
self._infos.get(CONF_USE_AUTO_START_STOP_FEATURE) is True
self._infos.get(CONF_USE_AUTO_START_STOP_FEATURE, False) is True
and self._infos.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_CLIMATE
)
@@ -145,12 +145,17 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
CONF_USE_PRESETS_CENTRAL_CONFIG,
CONF_USE_PRESENCE_CENTRAL_CONFIG,
CONF_USE_ADVANCED_CENTRAL_CONFIG,
CONF_USE_CENTRAL_MODE,
):
if not is_empty:
current_config = self._infos.get(config, None)
self._infos[config] = current_config is True or (
current_config is None and self._central_config is not None
self._infos[config] = self._central_config is not None and (
current_config is True or current_config is None
)
# self._infos[config] = current_config is True or (
# current_config is None and self._central_config is not None
# )
else:
self._infos[config] = self._central_config is not None
@@ -209,6 +214,9 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
CONF_USE_PRESENCE_CENTRAL_CONFIG,
CONF_USE_PRESETS_CENTRAL_CONFIG,
CONF_USE_ADVANCED_CENTRAL_CONFIG,
CONF_USE_CENTRAL_MODE,
# CONF_USE_CENTRAL_BOILER_FEATURE, this is for Central Config
CONF_USED_BY_CENTRAL_BOILER,
]:
if data.get(conf) is True:
_LOGGER.error(
@@ -306,6 +314,22 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
):
return False
if (
infos.get(CONF_PROP_FUNCTION, None) == PROPORTIONAL_FUNCTION_TPI
and infos.get(CONF_USE_TPI_CENTRAL_CONFIG, False) is False
and (
infos.get(CONF_TPI_COEF_INT, None) is None
or infos.get(CONF_TPI_COEF_EXT) is None
)
):
return False
if (
infos.get(CONF_USE_PRESETS_CENTRAL_CONFIG, False) is True
and self._central_config is None
):
return False
return True
def merge_user_input(self, data_schema: vol.Schema, user_input: dict):
@@ -354,7 +354,11 @@ CONF_WINDOW_ACTIONS = [
CONF_WINDOW_ECO_TEMP,
]
SUPPORT_FLAGS = ClimateEntityFeature.TARGET_TEMPERATURE | ClimateEntityFeature.TURN_OFF | ClimateEntityFeature.TURN_ON
SUPPORT_FLAGS = (
ClimateEntityFeature.TARGET_TEMPERATURE
| ClimateEntityFeature.TURN_OFF
| ClimateEntityFeature.TURN_ON
)
SERVICE_SET_PRESENCE = "set_presence"
SERVICE_SET_PRESET_TEMPERATURE = "set_preset_temperature"
@@ -31,6 +31,10 @@ from .auto_start_stop_algorithm import (
)
_LOGGER = logging.getLogger(__name__)
_LOGGER_ENERGY = logging.getLogger(
"custom_components.versatile_thermostat.energy_debug"
)
HVAC_ACTION_ON = [ # pylint: disable=invalid-name
HVACAction.COOLING,
@@ -97,7 +101,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
"""Initialize the Thermostat"""
super().post_init(config_entry)
for climate in config_entry.get(CONF_UNDERLYING_LIST):
self._underlyings.append(
UnderlyingClimate(
@@ -549,6 +553,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
] = self._auto_start_stop_algo.accumulated_error_threshold
self.async_write_ha_state()
_LOGGER.debug(
"%s - Calling update_custom_attributes: %s",
self,
@@ -595,8 +600,18 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
if self._total_energy is None:
self._total_energy = added_energy
_LOGGER_ENERGY.debug(
"%s - incremente_energy set energy is %s",
self,
self._total_energy,
)
else:
self._total_energy += added_energy
_LOGGER_ENERGY.debug(
"%s - incremente_energy incremented energy is %s",
self,
self._total_energy,
)
_LOGGER.debug(
"%s - added energy is %.3f . Total energy is now: %.3f",
@@ -837,7 +852,8 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
changes = True
# try to manage new target temperature set if state if no other changes have been found
if not changes:
# and if a target temperature have already been sent
if not changes and under.last_sent_temperature is not None:
_LOGGER.debug(
"Do temperature check. under.last_sent_temperature is %s, new_target_temp is %s",
under.last_sent_temperature,
@@ -21,7 +21,9 @@ from .underlyings import UnderlyingSwitch
from .prop_algorithm import PropAlgorithm
_LOGGER = logging.getLogger(__name__)
_LOGGER_ENERGY = logging.getLogger(
"custom_components.versatile_thermostat.energy_debug"
)
class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
"""Representation of a base class for a Versatile Thermostat over a switch."""
@@ -183,8 +185,18 @@ class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
if self._total_energy is None:
self._total_energy = added_energy
_LOGGER_ENERGY.debug(
"%s - incremente_energy set energy is %s",
self,
self._total_energy,
)
else:
self._total_energy += added_energy
_LOGGER_ENERGY.debug(
"%s - incremente_energy increment energy is %s",
self,
self._total_energy,
)
self.update_custom_attributes()
@@ -25,7 +25,9 @@ from .const import (
from .underlyings import UnderlyingValve
_LOGGER = logging.getLogger(__name__)
_LOGGER_ENERGY = logging.getLogger(
"custom_components.versatile_thermostat.energy_debug"
)
class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=abstract-method
"""Representation of a class for a Versatile Thermostat over a Valve"""
@@ -265,8 +267,18 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
if self._total_energy is None:
self._total_energy = added_energy
_LOGGER_ENERGY.debug(
"%s - incremente_energy set energy is %s",
self,
self._total_energy,
)
else:
self._total_energy += added_energy
_LOGGER_ENERGY.debug(
"%s - get_my_previous_state increment energy is %s",
self,
self._total_energy,
)
self.update_custom_attributes()
@@ -64,7 +64,7 @@
"use_motion_feature": "Use motion detection",
"use_power_feature": "Use power management",
"use_presence_feature": "Use presence detection",
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after seecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after selecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
"use_auto_start_stop_feature": "Use the auto start and stop feature"
}
},
@@ -547,4 +547,4 @@
}
}
}
}
}
@@ -150,10 +150,11 @@ class VersatileThermostatAPI(dict):
return entity.state
return None
async def init_vtherm_links(self):
async def init_vtherm_links(self, entry_id=None):
"""Initialize all VTherms entities links
This method is called when HA is fully started (and all entities should be initialized)
Or when we need to reload all VTherm links (with Number temp entities, central boiler, ...)
If entry_id is set, only the VTherm of this entry will be reloaded
"""
await self.reload_central_boiler_binary_listener()
await self.reload_central_boiler_entities_list()
@@ -175,7 +176,8 @@ class VersatileThermostatAPI(dict):
entity.device_info
and entity.device_info.get("model", None) == DOMAIN
):
await entity.async_startup(self.find_central_configuration())
if entry_id is None or entry_id == entity.unique_id:
await entity.async_startup(self.find_central_configuration())
async def init_vtherm_preset_with_central(self):
"""Init all VTherm presets when the VTherm uses central temperature"""
+563 -303
View File
File diff suppressed because it is too large Load Diff
+72
View File
@@ -320,6 +320,78 @@ async def test_bug_101(
assert entity.preset_mode is PRESET_NONE
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_615(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that when a underlying climate target temp is changed, the VTherm don't change its own temperature target if no
target_temperature have already been sent"""
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data=PARTIAL_CLIMATE_NOT_REGULATED_CONFIG, # 5 minutes security delay
)
# Underlying is in HEAT mode but should be shutdown at startup
fake_underlying_climate = MockClimate(
hass, "mockUniqueId", "MockClimateName", {}, HVACMode.HEAT, HVACAction.HEATING
)
# 1. create the thermostat
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
), patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=fake_underlying_climate,
):
vtherm = await create_thermostat(hass, entry, "climate.theoverclimatemockname")
assert vtherm
assert vtherm.name == "TheOverClimateMockName"
assert vtherm.is_over_climate is True
assert vtherm.hvac_mode is HVACMode.OFF
# because in MockClimate HVACAction is HEATING if hvac_mode is not set
assert vtherm.hvac_action is HVACAction.HEATING
# Force a preset_mode without sending a temperature (as it was restored with a preset)
vtherm._attr_preset_mode = PRESET_BOOST
assert vtherm.target_temperature == vtherm.min_temp
assert vtherm.preset_mode is PRESET_BOOST
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
) as mock_underlying_set_hvac_mode:
# 2. Change the target temp of underlying thermostat at now + 1 min
now = now + timedelta(minutes=1)
await send_climate_change_event_with_temperature(
vtherm,
HVACMode.OFF,
HVACMode.OFF,
HVACAction.OFF,
HVACAction.OFF,
now,
25,
True,
"climate.mock_climate", # the underlying climate entity id
)
# Should NOT have been taken the new target temp nor have change the preset
assert vtherm.target_temperature == vtherm.min_temp
assert vtherm.preset_mode is PRESET_BOOST
mock_underlying_set_hvac_mode.assert_not_called()
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_508(